  1. Hallo Sebastian, Standort Abholung bieten wir nicht an. Die Gründe dafür liegen in der Verwaltung davon. Sorry, Bastian
  2. Hi, the sample rate depends on the measured distance. For small distances (a few meters) the sample rate is 100Hz. When using the sensor in full range (40m) the sample rate declines to 10Hz.
  3. Hi, The purpose of the varistor is to protect the mosfets for overvoltage. To be honest, I didn't know. I could imagine that it is to decrease the leakage current.
  4. Hi, there is no specific frequency to be cut out. It is only intended to filter a possible ripple. I'm not completely sure why the ADC ground is AGND. Maybe there was a reason for this, but I did not remember. In fact it might be better to connect the ADC to the 3.3V (digital) ground. Kind regards, Bastian
  5. Sneak Preview: 11 new Bricklets: Blogentry
  6. Sneak Preview: 11 neue Bricklets: Blogeintrag
  7. Neues Zubehör im Shop: Blogeintrag
  8. New Accessories in the Shop: Blogentry
  9. Ein Problem kann das parallele Verlegen von 230V Leitungen und Bricklet Leitungen sein. Kannst du diese getrennt verlegen? Grüße, Bastian
  10. batti

    Ideen zu Fehlersuche

    Sinnvoll ist es 230V und Versorgungsleitungen möglichst weit weg von Brickletkabeln etc. zu verlegen.
  11. batti

    Ideen zu Fehlersuche

    Hallo Sid, kannst du von dem Aufbau ein Foto machen? Die Pumpe, Magnetschalter etc. sind nicht aktiv, korrekt? Gut wäre es, wenn du probieren könntest den Aufbau zu verkleinern, so dass irgendwann ein minimaler Aufbau exisitiert um das Problem zu erzeugen. Viele Grüße, Bastian
  12. Hallo Lunix, die Hardware des Remote Switch Bricklets sollte dies können. Allerdings vermutlich die aktuelle Software (Firmware) nicht, sofern der Handsender nicht zufällig eine der unterstützen Adressierungsarten nutzt. Im Zweifelsfall müsstest du die Firmware modifizieren. Grüße, Bastian
  13. The order is marked as not marked as paid. Our payment provider give us the information "transaction declined by authorization system". The reasons for this can be manifold. Unfortunately we don't have any possibilities to influence this. You could try to ask your credit card company for the reasons. If you have no paypal account you can try using paypal to pay with credit card. If you have a paypal account paypal will only let you pay with your account. Sorry for the problems, Bastian
  14. Thats weird. I have justed tested it and it works. You never see the fields or have you pressed "next"?
  15. Ah, ich verstehe. Kannst du diese Kabel für Tests weiter von den Bricks/Bricklets entfernen?
  16. Danke für das Foto. Sind bei den Kabeln die in die Runde geführt werden irgendwelche spannungsführenden dabei? Falls möglich kannst du mal probieren alle Kabel möglichst weit weg von den Bricks/Bricklets zu halten. Tritt das Problem dann auch noch auf?
  17. Hallo Robin, ist vll. ein Pin krumm? Siehe hier Sonst probier es mal mit Kraft den Stecker gerade einzustecken. Grüße, Bastian
  18. Hallo Stephan, wie führst du die 230V Leitungen? Kannst du diese mit einem größeren Abstand zu dem Brick/Bricklet Aufbau verlegen? Grüße, Bastian
  19. Was ist das denn für ein Aufbau? Was ist angeschlossen?
  20. Ist gefixt.
  21. If you change the resistor value keep the maximum input voltage of the ADC in mind. Bastian
  22. Master Bricks with 12mm stack connectors, new RED Brick Image, openHAB and Nagios as services available and update of Starter Kit: Server Room Monitoring Blogentry
  23. Master Bricks ab jetzt mit 12mm Steckern, neues RED Brick Image, openHAB und Nagios als Services und Update des Starterkits: Serverraum-Überwachung Blogeintrag
  24. Merkwürdig... Meld dich bitte wieder falls es wieder auftritt.
  25. Teste bitte mal, wie beschrieben, nur mit der Funksteckdose ohne angeschlossenem Venti.
×
×